{"product_id":"nti-enviromux-e-aclm-3p480-3-phasen-ac-voltage-monitor-power-uberwachung-480-vac","title":"NTI Enviromux E-ACLM-3P480 3-Phasen AC Voltage Monitor Power Überwachung 480 VAC","description":"\u003cbody\u003e\n \n \n \n \n \u003cdiv align=\"center\"\u003e\u003cfont face=\"Arial\" size=\"6\"\u003e\u003cb\u003eNTI Enviromux E-ACLM-3P480 3-Phasen AC Voltage Monitor Power Überwachung 480 VAC\u003c\/b\u003e\u003c\/font\u003e\u003c\/div\u003e\n\u003cdiv align=\"center\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cdiv align=\"center\"\u003e\u003cb\u003e\u003cspan style=\"font-size: x-large;\"\u003e✔️ New \u0026amp; sealed in orignal Box\u003c\/span\u003e\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv align=\"center\"\u003e\u003cfont face=\"Arial\" size=\"5\"\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/font\u003e\u003c\/div\u003e\n\u003cdiv align=\"center\"\u003e\u003cb\u003e\u003cfont size=\"6\"\u003eFeatures:\u003c\/font\u003e\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv align=\"center\"\u003e\u003cb\u003e\u003cspan style=\"font-size: x-large;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cb\u003e\u003cspan style=\"font-size: x-large;\"\u003e✔️ Modell:\u003c\/span\u003e\u003cfont size=\"5\"\u003e \u003c\/font\u003e\u003c\/b\u003e\u003cb style=\"font-family: Arial;\"\u003e\u003cfont size=\"5\"\u003eE-ACLM-3P480\u003c\/font\u003e\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv align=\"center\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cb\u003e\u003cspan style=\"font-size: x-large;\"\u003e✔️ \u003c\/span\u003e\u003c\/b\u003e\u003cfont face=\"Arial\" size=\"5\"\u003e\u003cb\u003eManufacturer: NTI, Network Technologies Incorporated USA\u003c\/b\u003e\u003c\/font\u003e\n\u003c\/div\u003e\n\u003cdiv align=\"center\"\u003e\u003cstrong style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv align=\"center\"\u003e\u003cstrong style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv align=\"center\" style=\"text-align: center; \"\u003e\n\u003cstrong style=\"text-align: left;\"\u003eMeasured and Reported Values\u003c\/strong\u003e\u003cspan style=\"text-align: left;\"\u003e:\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv align=\"center\" style=\"text-align: center; \"\u003e\u003cspan style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv align=\"center\" style=\"text-align: center; \"\u003e\u003cspan style=\"text-align: left;\"\u003eTrue RMS Voltage\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv align=\"center\" style=\"text-align: center; \"\u003e\u003cspan style=\"text-align: left;\"\u003eRMS Current\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv align=\"center\" style=\"text-align: center; \"\u003e\u003cspan style=\"text-align: left;\"\u003eActive Power\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv align=\"center\" style=\"text-align: center; \"\u003e\u003cspan style=\"text-align: left;\"\u003eReactive Power\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv align=\"center\" style=\"text-align: center; \"\u003e\u003cspan style=\"text-align: left;\"\u003eFrequency, phase angle, and power factor (not used for alerts or data logging)\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv align=\"center\" style=\"text-align: center; \"\u003e\u003cstrong style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv align=\"center\" style=\"text-align: center; \"\u003e\n\u003cstrong style=\"text-align: left;\"\u003eMonitoring\u003c\/strong\u003e\u003cspan style=\"text-align: left;\"\u003e:\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv align=\"center\" style=\"text-align: center; \"\u003e\u003cspan style=\"text-align: left;\"\u003eMonitors single or three-phase circuit (not multiple independent single-phase circuits)\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv align=\"center\" style=\"text-align: center; \"\u003e\u003cspan style=\"text-align: left;\"\u003eMeasurements per phase basis\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cli\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003eRequirements:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003e\u003cstrong\u003eCurrent and power measurements require current transformers (sold separately)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003e\u003cstrong\u003eMeasurement update rate: once per second (via software)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003e\u003cstrong\u003eSupports 24 AWG CAT5\/5e\/6 cable up to 300 feet (91 m)\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003eCurrent Transformer Connection:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003e\u003cstrong\u003eThree 2-wire terminal blocks for easy attachment of optional current transformers (16-26 AWG wires)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003e\u003cstrong\u003eSplit-core current transformers allow installation without disconnecting conductors\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003e\u003cstrong\u003eAccuracy and range depend on current transformer used\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003eVoltage Specifications:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\u003cli style=\"text-align: left;\"\u003e\u003cstrong\u003eIsolated 4-wire terminal block for primary voltage sample (bare-wire or crimp terminal)\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003eElectrical Details:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003e\u003cstrong\u003eFrequency: 50\/60 Hz\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003e\u003cstrong\u003eMaximum primary current: limited by current transformer used\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003e\u003cstrong\u003ePowered by ENVIROMUX-2D\/5D\/16D\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/div\u003e\u003c\/li\u003e\n\u003cul\u003e\u003cli style=\"text-align: left;\"\u003e\u003cstrong\u003eDimensions (WxDxH): 6.82 x 3.0 x 1.725 inches (173 x 76 x 44 mm)\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003eOther:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003e\u003cstrong\u003eCompatible with ENVIROMUX-FSC Fiber Converter\/Extender\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003e\u003cstrong\u003eExtends sensor up to 1.2 miles (2 km) from ENVIROMUX unit\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\u003cbr\u003e\u003c\/li\u003e\n\u003c\/div\u003e\n\u003cdiv align=\"center\"\u003e\u003cb\u003e\u003cfont size=\"4\"\u003e\u003cbr\u003e\u003c\/font\u003e\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv align=\"center\"\u003e\u003cfont size=\"4\"\u003e\u003cb\u003eItem-ID: \u003cfont face=\"Arial\"\u003eE-ACLM-3P480\u003c\/font\u003e\u003c\/b\u003e\u003c\/font\u003e\u003c\/div\u003e\n\u003cdiv align=\"center\"\u003e\u003cfont face=\"Arial\"\u003e\u003cbr\u003e\u003c\/font\u003e\u003c\/div\u003e\n\u003cdiv align=\"center\"\u003e\u003cfont face=\"Arial\"\u003e\u003cbr\u003e\u003c\/font\u003e\u003c\/div\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cdiv align=\"center\"\u003e\u003cfont color=\"#0039f3\" face=\"Arial\" size=\"5\"\u003e\u003cb\u003eIf you have any questions, please contact us!\u003c\/b\u003e\u003c\/font\u003e\u003c\/div\u003e\n\u003cdiv align=\"center\"\u003e\u003cfont color=\"#0039f3\" face=\"Arial\" size=\"5\"\u003e\u003cb\u003ewe always respond within 24 hours.\u003c\/b\u003e\u003c\/font\u003e\u003c\/div\u003e\n\u003cdiv align=\"center\"\u003e\u003cfont color=\"#0039f3\" face=\"Arial\" size=\"5\"\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/font\u003e\u003c\/div\u003e\n\u003cdiv align=\"center\"\u003e\u003cfont color=\"#0039f3\" face=\"Arial\" size=\"4\"\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/font\u003e\u003c\/div\u003e\n\u003cdiv align=\"center\"\u003e\u003cfont color=\"#0039f3\" face=\"Arial\" size=\"4\"\u003e\u003cb\u003eFor buyers within the EU, VAT is shown separately on the invoice.\u003c\/b\u003e\u003c\/font\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n \n \u003cdiv\u003eManufacturer: \u003cbr\u003eOllis Collectibles, Inh. Oliver Wanzek\u003cbr\u003eSchöninger Stieg 12\u003cbr\u003eDE-38381 Jerxheim\u003cbr\u003eEmail: ollis.collectibles@gmail.com\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/body\u003e","brand":"NTI","offers":[{"title":"Default Title","offer_id":54408717238536,"sku":"11508","price":66.49,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0745\/7544\/6280\/files\/57_95926e8e-5cb1-40ef-a2f8-f6fdc5595f61.jpg?v=1774134764","url":"https:\/\/www.ollis-collectibles.de\/en\/products\/nti-enviromux-e-aclm-3p480-3-phasen-ac-voltage-monitor-power-uberwachung-480-vac","provider":"Olli's Collectibles","version":"1.0","type":"link"}